[1] |
Martínez-Palmer A,Gómez-FaiňP,Espaňa-Albelda A,et al.Visual function with bilateral implantation of monofocal and multifocal intraocular lenses: a prospective, randomized,controlled clinical trial[J].J Refract Surg,2008,24(3):257-264.
|
[2] |
Hantera MM,Hamed AM,Fekry Y,et al.Initial experience with an accommodating intraocular lens:controlled prospective study[J].JCataract Refract Surg,2010,36(7):1167-1172.
|
[3] |
Küchle M, Seitz B, Langenbucher A, et al.Erlangen Accommodative Intraocular Lens Study Group.Stability of refraction,accommodation,and lens position after implantation of the 1CU accommodating posterior chamber intraocular lens[J].J Cataract Refract Surg,2003,29(12):2324-2329.
|
[4] |
Nawa Y,Ueda T,Nakatsuka M,et al.Accommodation obtained per 1.0 mm forward movement of a posterior chamber intraocular lens[J].J Cataract Refract Surg,2003,29(11):2069-2072.
|
[5] |
AlióJL,Plaza-Puche AB,Montalban R,et al.Visual outcomes with a single-optic accommodating intraocular lens and a lowaddition-power rotational asymmetric multifocal intraocular lens[J].JCataract Refract Surg,2012,38(6):978-985.
|
[6] |
Cumming JS,Colvard DM,Dell SJ,et al.Clinical evaluation of the Crystalens AT-45 accommodating intraocular lens:results of the U.S.Food and Drug Administration clinical trial[J].J Cataract Refract Surg,2006,32(5):812-825.
|
[7] |
Stachs O,Schneider H,Beck R,et al.Pharmacological-induced haptic changes and the accommodative performance in patients with the AT-45 accommodative IOL[J].J Refract Surg,2006,22(2):145-150.
|
[8] |
Jardim D,Soloway B, Starr C.Asymmetric vault of an accommodating intraocular lens[J].J Cataract Refract Surg,2006,32(2):347-350.
|
[9] |
Maxwell WA,Lane SS,Zhou F.Performance of presbyopiacorrecting intraocular lenses in distance optical bench tests[J].J Cataract Refract Surg,2009,35(1):166-171.
|
[10] |
Yuen L,Trattler W,Boxer Wachler BS.Two cases of Z syndrome with the Crystalens after uneventful cataract surgery[J].JCataract Refract Surg,2008,34(11):1986-1989.
|
[11] |
Karavitaki AE,Pallikaris IG,Panagopoulou SI,et al.Long-term visual outcomes after Crystalens(® ) HD intraocular lens implantation[J].Clin Ophthalmol,2014,8:937-943.
|
[12] |
Dick HB.Accommodative intraocular lenses:current status[J].Curr Opin Ophthalmol,2005,16(1):8-26.
|
[13] |
Mastropasqua L,Toto L,Falconio G,et al.Longterm results of 1 CU accommodative intraocular lens implantation:2-year follow-up study[J].Acta Ophthalmol Scand,2007,85(4):409-414.
|
[14] |
Ong HS,Evans JR,Allan BD.Accommodative intraocular lens versus standard monofocal intraocular lens implantation in cataract surgery[J].Cochrane Database Syst Rev, 2014, 2014(5):CD009667.
|
[15] |
刘新泉,李明飞,郭鸣华,等.1CU可调节式人工晶状体植入的长期临床观察[J].中华眼科杂志,2010,46(5):415-418.
|
[16] |
Harman FE,Maling S,Kampougeris G,et al.Comparing the 1CU accommodative, multifocal, and monofocal intraocular lenses:a randomized trial[J].Ophthalmology,2008,115(6):993-1001.
|
[17] |
Sheppard AL,Bashir A,Wolffsohn JS,et al.Accommodating intraocular lenses:a review of design concepts,usage and assessment methods[J].Clin Exp Optom,2010,93(6):441-452.
|
[18] |
Brown D,Dougherty P,Gills JP,et al.Functional reading acuity and performance:Comparison of 2 accommodating intraocular lenses[J].JCataract Refract Surg,2009,35(10):1711-1714.
|
[19] |
Brown D,Dougherty P,Gills JP,et al.Functional reading acuity and performance:Comparison of 2 accommodating intraocular lenses[J].JCataract Refract Surg,2009,35(10):1711-1714.
|
[20] |
Sanders DR,Sanders ML.Tetraflex Presbyopic IOL Study Group.US FDA clinical trial of the Tetraflex potentially accommodating IOL: comparison to concurrent age-matched monofocal controls[J].J Refract Surg,2010,26(10):723-730.
|
[21] |
Sanders DR,Sanders ML.Visual performance results after Tetraflex accommodating intraocular lens implantation[J].Ophthalmology.2007,114(9):1679-1684.
|
[22] |
Dong Z,Wang NL,Li JH.Vision,subjective accommodation and lens mobility after TetraFlex accommodative intraocular lens implantation[J].Chin Med J(Engl),2010,123(16):2221-2224.
|
[23] |
Wolffsohn JS,Davies LN,Gupta N,et al.Mechanism of action of the tetraflex accommodative intraocular lens[J].J Refract Surg,2010,26(11):858-862.
|
[24] |
Kramer GD,Werner L,Neuhann T,et al.Anterior haptic flexing and in-the-bag subluxation of an accommodating intraocular lens due to excessive capsular bag contraction[J].J Cataract Refract Surg,2015,41(9):2010-2013.
|
[25] |
Sadoughi MM,Einollahi B,Roshandel D,et al.Visual and refractive outcomes of phacoemulsification with implantation of accommodating versus standard monofocal intraocular lenses[J].JOphthalmic Vis Res,2015,10(4):370-374.
|
[26] |
Pepose JS,Burke J,Qazi M.Accommodating Intraocular Lenses[J].Asia Pac JOphthalmol(Phila),2017,6(4):350-357.
|
[27] |
McLeod SD,Vargas LG,Portney V,et al.Synchrony dual-optic accommodating intraocular lens.Part 1: optical and biomechanical principles and design considerations[J].J Cataract Refract Surg,2007,33(1):37-46.
|
[28] |
Marques EF,Castanheira-Dinis A.Clinical performance of a new aspheric dual-optic accommodating intraocular lens[J].Clin Ophthalmol,2014,8:2289-2295.
|
[29] |
Bohórquez V,Alarcon R.Long-term reading performance in patients with bilateral dual-optic accommodating intraocular lenses[J].JCataract Refract Surg,2010,36(11):1880-1886.
|
[30] |
Glasser A.Restoration of accommodation:surgical options for correction of presbyopia[J].Clin Exp Optom,2008,91(3):279-295.
|
[31] |
Ossma IL,Galvis A,Vargas LG,et al.Synchrony dual-optic accommodating intraocular lens.Part 2:pilot clinical evaluation[J].JCataract Refract Surg,2007,33(1):47-52.
|
[32] |
AlióJL,Plaza-Puche AB,Montalban R,et al.Near visual outcomes with single-optic and dual-optic accommodating intraocular lenses[J].JCataract Refract Surg,2012,38:1568-1575.
|
[33] |
Sarfarazi FM.Sarfarazi dual optic accommodative intraocular lens[J].Ophthalmol Clin North Am,2006,19(1):125-128.
|
[34] |
AlióJL,Alió-Del-Barrio JL,Vega-Estrada A.Accommodative intraocular lenses:where are we and where we are going[J].Eye Vis(Lond),2017,4:16.
|
[35] |
Alio JL,Simonov A,Plaza-Puche AB,et al.Visual Outcomes and Accommodative Response of the Lumina Accommodative Intraocular Lens[J].Am J Ophthalmol,2016,164:37-48.
|
[36] |
AlióJL,Ben-nun J,Rodríguez-Prats JL,et al.Visual and accommodative outcomes 1 year after implantation of an accommodating intraocular lens based on a new concept[J].J Cataract Refract Surg,2009,35(10):1671-1678.
|
[37] |
Ben-Nun J,AlióJL.Feasibility and development of a high-power real accommodating intraocular lens[J].JCataract Refract Surg,2005,31(9):1802-1808.
|
[38] |
Studeny P,Krizova D,Urminsky J.Clinical experience with the WIOL-CF accommodative bioanalogic intraocular lens:Czech national observational registry[J].Eur J Ophthalmol,2016,26(3):230-235.
|
[39] |
Wörtz GN,Wörtz PR.Refractive IOL Pipeline:Innovations,Predictions,and Needs[J].Curr Ophthalmol Rep,2017,5:255-263.
|
[40] |
Pallikaris IG,Portaliou DM,Kymionis GD,et al.Outcomes after accommodative bioanalogic intraocular lens implantation[J].J Refract Surg,2014,30(6):402-406.
|
[41] |
Lee YH,Kim YC.In-the-bag dislocation of polyfocal full-optics accommodative intraocular lens:A case report[J].Indian J Ophthalmol,2019,67(7):1200-1202.
|
[42] |
Kang KT, Kim YC.Dislocation of polyfocal full-optics accommodative intraocular lens after neodymium-doped yttrium aluminum garnet capsulotomy in vitrectomized eye[J].Indian J Ophthalmol,2013,61(11):678-680.
|
[43] |
Kim YC,Kang KT,Yeo Y,et al.Consistent pattern in positional instability of polyfocal full-optics ac-commodative IOL[J].Int Ophthalmol,2017,37(6):1299-1304.
|
[44] |
Floyd AM,Werner L,Liu E,et al.Capsular bag opacification with a new accommodating intraocular lens[J].JCataract Refract Surg,2013,39(9):1415-1420.
|
[45] |
Kohl JC,Werner L,Ford JR,et al.Long-term uveal and capsular biocompatibility of a new accommodating intraocular lens[J].J Cataract Refract Surg,2014,40(12):2113-2119.
|
[46] |
Pepose JS,Burke J,Qazi M.Accommodating Intraocular Lenses[J].Asia Pac J Ophthalmol(Phila),2017,6(4):350-357.
|
[47] |
Garg S,De-Jesus MT,Fletcher LM,et al.Twelve-month clinical outcomes after implantation of a new,modular,anterior shapechanging fluid optic intraocular lens[J].JCataract Refract Surg,2022,48(10):1134-1140.
|
[48] |
Bontu S,Werner L,Kennedy S,et al.Long-term uveal and capsular biocompatibility of a new fluid-filled, modular accommodating intraocular lens[J].J Cataract Refract Surg,2021,47(1):111-117.
|
[49] |
Qin C,Fei F,Wei Y,et al.Thermo-sensitive Poloxamer based antibacterial anti-inflammatory and photothermal conductive multifunctional hydrogel as injectable,in situ curable and adjustable intraocular lens[J].Bioact Mater,2024,41:30-45.
|
[50] |
Cabezas M.Intraocular lenses in cataract surgery in Chile:An updated review[J].Revista Médica Clínica Las Condes,2023,34(5):359-369.
|
[51] |
Moshirfar M,Martin DJ,Jensen JL,et al.Light adjustable intraocular lenses:an updated platform for cataract surgery[J].Curr Opin Ophthalmol,2023,34(1):78-83.
|
[52] |
Schojai M,Schultz T,Schulze K,et al.Long-term follow-up and clinical evaluation of the light-adjustable intraocular lens implanted after cataract removal:7-year results[J].J Cataract Refract Surg,2020,46(1):8-13.
|
[53] |
Hengerer FH,Böcker J,Dick BH,et al.Light adjustable lens.New options for customized correction of presbyopia[J].Ophthalmologe,2012,109(7):676-682.
|