中华眼科医学杂志(电子版) ›› 2021, Vol. 11 ›› Issue (06) : 375 -379. doi: 10.3877/cma.j.issn.2095-2007.2021.06.010

综述

角膜屈光手术术前筛查早期圆锥角膜的研究进展
刘佳1, 贺瑞2,(), 李晓娜3, 高妍2   
  1. 1. 030001 太原,山西医科大学第一临床医学院2019级研究生
    2. 030002 太原,山西省眼科医院准分子激光科
    3. 030024 太原,太原理工大学生物医学工程学院
  • 收稿日期:2021-04-28 出版日期:2021-12-28
  • 通信作者: 贺瑞
  • 基金资助:
    国家自然科学基金项目(12072218); 山西省卫计委科技攻关项目(2017099)

Research progress of early keratoconus screening before refractive surgery

Jia Liu1, Rui He2,(), Xiaona Li3, Yan Gao2   

  1. 1. Master′s degree 2019, the First Clinical Medical College of Shanxi Medical University, Taiyuan 030001, China
    2. Excimer Laser, Shanxi Eye Hospital, Taiyuan 030002, China
    3. College of Biomedical Engineering Taiyuan University of Technology, Taiyuan 030024, China
  • Received:2021-04-28 Published:2021-12-28
  • Corresponding author: Rui He
引用本文:

刘佳, 贺瑞, 李晓娜, 高妍. 角膜屈光手术术前筛查早期圆锥角膜的研究进展[J]. 中华眼科医学杂志(电子版), 2021, 11(06): 375-379.

Jia Liu, Rui He, Xiaona Li, Yan Gao. Research progress of early keratoconus screening before refractive surgery[J]. Chinese Journal of Ophthalmologic Medicine(Electronic Edition), 2021, 11(06): 375-379.

目前,角膜屈光手术是许多近视眼患者的选择,但术后继发性圆锥角膜会严重损害患者的视力。有研究结果表明,术前筛查圆锥角膜是预防继发性圆锥角膜发生的重要手段之一。本文中笔者对角膜屈光手术术前筛查圆锥角膜的检查设备和检查方法进行汇总,并重点阐述角膜地形图和角膜生物力学检查各项参数的研究进展,以期为临床应用的选择提供参考。

Refractive surgery is the choice of many myopia patients. However, secondary keratoconus, a postoperative complication, has the great harm to the visual acuity of patients. The one of the important means to prevent it is to screen preoperatively. Therefore, the examination of keratoconus before corneal refractive surgery was summarized, and the parameters of corneal topographic map and corneal biomechanical examination was compared, which to provide a reference for clinical choice.

图2 患者左眼Pentacam的圆锥角膜检查结果 图2A示角膜前表面曲率图,基本呈对称领结型;图2B示前表面高度图,基本对称,前表面最高点+5 mm,属正常范围;图2C示角膜厚度图,呈同心圆分布,角膜最薄点厚度为619 mm,属于正常范围;图2D示角膜后表面高度图,基本对称,后表面最高点为+16 mm,属可疑圆锥范围;Ambrosio Enhanced Ectasia Display-D为1.07,属正常范围,提示角膜形态学尚可;Corvis ST联合Pentacam检查获得的断层生物力学指数为0.48,提示患者左眼可疑有圆锥角膜,建议定期复查
表1 临床期圆锥角膜和亚临床期圆锥角膜的分类标准
表2 Corvis ST检测可重复性和准确性良好参数的文献汇总
[1]
隋瑶,邢建男,赵海霞. 圆锥角膜的诊断治疗现状及研究新进展[J]. 中国医药导报201613(29): 32-36.
[2]
Binder PS, Lindstrom RL, Doyle SR,et al.Keratoconus and corneal ectasia after LASIK[J].J Refract Surg,2005,21(6):749-752.
[3]
Renato A, Bradley RJ.Screening for ectasia risk: what are we screening for and how should we screen for it?[J].J Refract Surg,2013,29(4):230-232.
[4]
Hyun BG, Ryung KJ, Hoon KC,et al.Corneal topographic and tomographic analysis of fellow eyes in unilateral keratoconus patients using Pentacam[J].Am J Ophthalmol,2014,157(1):103-109.
[5]
Vázquez PRR, Galletti JD, Minguez N,et al.Pentacam scheimpflug tomography findings in topographically normal patients and subclinical keratoconus cases[J].Am J Ophthalmol,2014,158(1):32-40.
[6]
Seiler T, Quurke AW.Iatrogenic keratectasia after LASIK in a case of forme fruste keratoconus[J].J Cataract Refract Surg,1998,24(7):1007-1009.
[7]
徐艺,戴锦晖,褚仁远. 早期圆锥角膜患者的角膜后表面形态分析(英文)[J]. 复旦学报(医学版)200936(5): 543-548.
[8]
Silas MR, Hilkert SM, Reidy JJ,et al.Posterior keratoconus[J].Br J Ophthalmol,2018,102(7):863-867.
[9]
彭予苏,陈敏,田乐,等. 角膜形态学和生物力学参数对角膜后表面高度影响的研究[J]. 中华眼科杂志2020, 56(2): 110-117.
[10]
Ambrósio R, Alonso RS, Luz A,et al.Corneal-thickness spatial profile and corneal-volume distribution: Tomographic indices to detect keratoconus[J].J Cataract Refract Surg,2006,32(11):1851-1859.
[11]
Piñero DP, Alió Jorge L, Alicia A,et al.Corneal volume, pachymetry, and correlation of anterior and posterior corneal shape in subclinical and different stages of clinical keratoconus[J].J Cataract Refract Surg,2010,36(5):814-825.
[12]
Uçakhan Ö, Çetinkor V, Özkan M,et al.Evaluation of Scheimpflug imaging parameters in subclinical keratoconus, keratoconus, and normal eyes[J].J Cataract Refract Surg,2011,37(6):1116-1124.
[13]
Song YW, He R, Ma JX,et al.Long-term safety of laser in situ keratomileusis in eyes with thin corneas: 5-year follow-up[J].Int J Ophthalmol,2018,11(7):1227-1233.
[14]
徐漫,孙荔,刘永珍,等. Belin角膜扩张分析鉴别早期圆锥角膜的敏感性与特异性[J]. 眼科新进展201535(5): 456-459.
[15]
Lopes BT, Ramos IC, Dawson DG,et al.Detection of ectatic corneal diseases based on pentacam[J].Z Med Phys,2016,26(2):136-142.
[16]
Hashemi H, Beiranvand A, Yekta A,et al.Pentacam top indices for diagnosing subclinical and definite keratoconus[J].J Curr Ophthalmol,2016,28(1):21-26.
[17]
Lopes BT, Ramos IC, Salomão MQ,et al.Enhanced tomographic assessment to detect corneal ectasia based on artificial intelligence[J].Am J Ophthalmol,2018,195:223-232.
[18]
Kreps EO, Marta J, Ikram I,et al.Repeatability of the Pentacam in various grades of keratoconus[J].Am J Ophthalmol,2020,219:154-162.
[19]
Guber I, McAlinden C, Majo F,et al.Identifying more reliable parameters for the detection of change during the follow-up of mild to moderate keratoconus patients[J].Eye Vis,2017,4(1):24-30.
[20]
曹雪倩,张章,王林农. 角膜生物力学测量及其临床应用新进展[J]. 医学研究生学报201629(3): 319-322.
[21]
Aghamohammadzadeh H, Newton RH, Meek KM.X-ray scattering used to map the preferred collagen orientation in the human cornea and limbus[J].Structure,2004,12(2):249-256.
[22]
Roberts CJ, Dupps WJ.Biomechanics of corneal ectasia and biomechanical treatments[J].J Cataract Refract Surg,2014,40(6):991-998.
[23]
Miki A, Maeda N, Asai T,et al.Measurement repeatability of the dynamic Scheimpflug analyzer[J].Jpn J Ophthalmol,2017,61(6):433-440.
[24]
Kenney MC, Chwa M, Atilano SR,et al.Increased levels of catalase and cathepsin V/l2 but decreased timp-1 in keratoconus corneas: evidence that oxidative stressplays a role in this disorder[J].Invest Ophthalmol Vis Sci,2005,46(3):823-832.
[25]
Saeed A, Bron AJ, Salvi SM,et al.Ultrastructural analysis of collagen fibrils and proteoglycans in keratoconus[J].Acta Ophthalmol,2008,86(7):764-772.
[26]
Ku JYF, Niederer RL, Patel DV,et al.Laser scanning in vivo confocal analysis of keratocyte density in keratoconus[J].Ophthalmology,2008,115(5):845-850.
[27]
Tian L, Ko MW, Wang LK,et al.Assessment of ocular biomechanics using dynamic ultra high-speed Scheimpflug imaging in keratoconic and normal eyes[J].J Refract Surg,2014,30(11):785-791.
[28]
Herber R, Terai N, Pillunat KR,et al.Dynamischer Scheimpflug-Analyzer (Corvis ST) zur Bestimmung kornealer biomechanischer parameter[J].Ophthalmologe,2018,115(8):635-643.
[29]
田磊,王丽强,孟晓丽,等. 应用可视化角膜生物力学分析仪评估不同阶段圆锥角膜生物力学特征[J]. 中华眼视光学与视觉科学杂志201416(5): 268-273.
[30]
McMonnies CW.Assessing corneal hysteresis using the Ocular Response Analyzer[J].Optom Vis Sci,2012,89(3):E343-E349.
[31]
Bao F, Geraghty B, Wang Q,et al.Consideration of corneal biomechanics in the diagnosis and management of keratoconus: is it important?[J].Eye Vis,2016,3(1):18-23.
[32]
田磊,黄一飞. 可视化角膜生物力学分析仪评估角膜生物力学特性的研究进展[J]. 解放军医学院学报201435(5): 502-505.
[33]
Atsuya M, Naoyuki M, Yasushi I,et al.Factors associated with corneal deformation responses measured with a dynamic scheimpflug analyzer[J].Invest Ophthalmol Vis Sci,2017,58(1):538-544.
[34]
Maeda N, Ueki R, Fuchihata M,et al.Corneal biomechanical properties in 3 corneal transplantation techniques with a dynamic Scheimpflug analyzer[J].Jpn J Ophthalmol,2014,58(6):483-489.
[35]
Asaoka R, Nakakura S, Tabuchi H,et al.The relationship between Corvis ST tonometry measured corneal parameters and intraocular pressure, corneal thickness and corneal curvature[J].PLoS One,2015,10:e0140385.
[36]
Hon Y, Lam AKC.Corneal deformation measurement using scheimpflug noncontact tonometry[J].Optom Vis Sci,2013,90(1):e1-e8.
[37]
Huseynova T, Waring GO, Roberts C,et al.Corneal biomechanicsas a function of intraocular pressure and pachymetry by dynamic in-frared signal and Scheimpflug imaging analysis in normal eyes[J].Am J Ophthalmol,2014,157(4):885-893.
[38]
Wang W, Du SL, Zhang XL.Corneal deformation response in patients with primary open-angle glaucoma and in healthy subjects analyzed by Corvis ST[J].Invest Ophthalmol Vis Sci,2015,56(9):5557-5565.
[39]
Ali NQ, Patel DV, McGhee CNJ.Biomechanical responses of healthy and keratoconic corneas measured using a noncontact Scheimpflug-based tonometer[J].Invest Ophthalmol Vis Sci,2014,55(6):3651-3659.
[40]
Kling S, Marcos S.Contributing factors to corneal deformation in air puff measurements[J].Invest Ophthalmol Vis Sci,2013,54(7):5078-5085.
[41]
Leung CK, Ye C, Weinreb RN.An ultra-high-speed scheimpflug camera for evaluation of corneal deformation response and its impact on IOP measurement[J].Invest Ophthalmol Vis Sci,2013,54(4):2885-2892.
[42]
Gabor N, Ziad H, Adrienne C,et al.Repeatability of ocular biomechanical data measurements with a Scheimpflug-based noncontact device on normal corneas[J].J Refract Surg,2013,29(8):558-563.
[43]
Riccardo V, Ahmed E, Roberts CJ,et al.Influence of pachymetry and intraocular pressure on dynamic corneal response parameters in healthy patients[J].J Refract Surg,2016,32(8):550-561.
[44]
Freitas VB, Renato A, Machado FB,et al.Effects of age on corneal deformation by non-contact tonometry integrated with an ultra-high-speed (UHS) Scheimpflug camera[J].Arq Bras Oftalmol,2013,76(4):229-232.
[45]
Zhao Y, Shen Y, Yan ZP,et al.Relationship among corneal stiffness, thickness, and biomechanical parameters measured by Corvis ST, Pentacam and ORA in keratoconus[J].Front Physiol,2019,10:740-748.
[46]
Ashkan E, Kai-Jung C, Riccardo V,et al.Determination of corneal biomechanical behaviorin-vivo for healthy eyes using CorVis ST tonometry: stress-strain index[J].Front Bioeng Biotechnol,2019,7:105-114.
[47]
Han F, Li M, Wei P,et al.Effect of biomechanical properties on myopia: a study of new corneal biomechanical parameters[J].BMC Ophthalmol,2020,20(1):459-466.
[48]
吴元,李晓丽,晏晓明,等. 基于Corvis ST的角膜生物力学参数在圆锥角膜诊断中的价值[J]. 中华实验眼科杂志201836(2): 130-134.
[49]
李欣宇,赵海霞. Covis ST与Pentacam眼前节分析仪测量近视眼患者中央角膜厚度的差异[J]. 山东医药201555(12): 29-30.
[50]
葛梅,田磊,王丽强,等. 可视化角膜生物力学分析仪与非接触眼压计和动态轮廓眼压计测量眼内压的一致性研究[J]. 解放军医学院学报201536(2): 101-104,108.
[51]
Riccardo V, Renato A, Ahmed E,et al.Detection of keratoconus with a new biomechanical index[J].J Refract Surg,2016,32(12):803-810.
[52]
Renato A, Lopes BT, Fernando F,et al.Integration of Scheimpflug-based corneal tomography and biomechanical assessments for enhancing ectasia detection[J].J Refract Surg,2017,33(7):434-443.
[53]
吴元,李晓丽,杨松霖,等. 应用CorVis ST对圆锥角膜及亚临床期圆锥角膜生物力学特性的研究及判别标准分析[J]. 北京大学学报(医学版)201951(5): 881-886.
[54]
肖明,马代金. 联合应用Corvis ST和Pentacam角膜地形图诊断圆锥角膜[J]. 眼科201928(2): 150-154.
[55]
李栋. 可视化角膜生物力学分析联合Pentacam相关指数诊断不同进展期圆锥角膜的研究[D]. 兰州:西北民族大学,2020.
[56]
Zhang MY, Zhang FJ, Li Y,et al.Early diagnosis of keratoconus in Chinese myopic eyes by combining Corvis ST with Pentacam[J].Curr Eye Res,2020,45(2):118-123.
[1] 崔梦凡, 贺瑞, 李晓娜, 陈维毅, 宋耀文. 角膜生物力学评估参数的应用进展[J]. 中华眼科医学杂志(电子版), 2023, 13(04): 236-240.
[2] 赵欣, 赵晴, 张华. 角膜地形图引导个性化切削屈光术矫正近视眼和散光的早期临床疗效[J]. 中华眼科医学杂志(电子版), 2023, 13(04): 210-214.
[3] 刘佳, 贺瑞, 李晓娜. 断层扫描生物力学指数应用于屈光手术术前早期圆锥角膜筛查的临床研究[J]. 中华眼科医学杂志(电子版), 2022, 12(06): 341-346.
[4] 马山, 刘秀花, 姜雅琴. IOLMaster700光学生物测量仪与Pentacam三维眼前节分析仪检测白内障患者眼部参数的临床研究[J]. 中华眼科医学杂志(电子版), 2021, 11(05): 280-285.
阅读次数
全文


摘要